CORRECTIVE MAITENANCE PROCESS - MALFUNTION REPORT
It's an ordinary corrective maintenance cycle but it differs in the following:
Mark the breakdown check box
Make sure that the technical object start-up date field is not empty
At the completion of the order fill in the malfunction end date and time fields
Create malfunction report ( technician in field)
The process flow is as follows
Release malfunction report (by engineering department)
Create breakdown maintenance order (pm01) or whatever the order type set is customized
Confirm operations And goods movements
Technically complete the order
Settle the order
Complete the business closure
Monitor the breakdown analysis - MTTR(Mean Time To Repair)/MTBR(Mean Time Between Replacement)
MCI7 - Breakdown Analysis by Equ/Floc/Object Class/Period
MCJB - through Equipment
MCJC - through Functional location T-CODES
Before monitoring make sure that the s070 info structure is updated by the period you want
And make sure that the object information is customized for only 1 completed order.