CORRECTIVE MAITENANCE PROCESS - MALFUNTION REPORT

It's an ordinary corrective maintenance cycle but it differs in the following:

Mark the breakdown check box 

Make sure that the technical object start-up date field is not empty

At the completion of the order fill in the malfunction end date and time fields

Create malfunction report ( technician in field)


The process flow is as follows

Release malfunction report (by engineering department)


Create breakdown maintenance order (pm01) or whatever the order type set is customized


Confirm operations And goods movements


Technically complete the order 


Settle the order 


Complete the business closure


Monitor the breakdown analysis - MTTR(Mean Time To Repair)/MTBR(Mean Time Between Replacement)

MCI7 - Breakdown Analysis by Equ/Floc/Object Class/Period 

MCJB - through Equipment

MCJC - through Functional location T-CODES


Before monitoring make sure that the s070 info structure is updated by the period you want

And make sure that the object information is customized for only  1 completed order.